ProvidentBrazeau Aug6 2008

Specs

SPECIFICATIONS:

Drive Cylinder (Gas Cylinder) :

- Operates on sweet or sour gas
- Maximum working pressure : 1500 psi
- Operates on Low Differential Pressure : 5-20 psi
- Variable operating speed up to 30 strokes/min.
- Gas INLET & OUTLET : 1 1/2" NPT

Optional Plunger Pumps :

- Available with 1,2 or 3 pumps, each independently adjustable in stroke length.
- For pumping liquids : eg. glycol, methanol, produced water
- Max discharge pressures : 1500 psi
- Capacity : adjustable from 0-50 USG/hr.

Air Compressor :

- Provides compressed air for instrumentation and chemical pumps
- Maximum air discharge pressure : 40 psi
- Capacity up to 3000 scfd. (approx. 2 scfm)

Frame :

- Small Footprint of 18" x 30" (bolted down to floor of skid).

Package :

- Housed in an insulated steel building on steel skid complete with heater and air receiver (see gallery).
- Building Dimensions: 36" Wide x 72" Long x 72" High


Various Pump Sizes and Capacities


Blair Air System - Pump Sizes and Capacities 1
1/2" Plunger (Area 0.19642 sq.in.)

Stroke In Inches

H - 2.55

G - 2.22

F - 1.89

E - 1.56

D - 1.23

C - 0.91

B - 0.58

A - 0.25

Strokes/min.

Litres/Day

232

215

185

154

124

94

63

49

20

Litres/Day

290

270

231

193

155

117

79

62

25

Litres/Day

347

324

278

232

186

140

95

75

30

Imperial Gallons/Day

76

71

61

51

41

30

20

16

30

1 Listed capacities may vary by approximately 10% due to inefficiencies that occur in fluid systems.


Blair Air System - Pump Sizes and Capacities 1
1 1/4" Plunger (Area 1.2266 sq.in.)

Stroke In Inches

MAX - 2.88

H - 2.55

G - 2.22

F - 1.89

E - 1.56

D - 1.23

C - 0.91

B - 0.58

A - 0.25

Strokes/min

Litres/Day

1666

1476

1285

1095

905

715

523

335

145

20

Litres/Day

2083

1845

1607

1369

1132

894

656

418

181

25

Litres/Day

2499

2214

1928

1644

1358

1073

788

503

217

30

Imperial Gallons/Day

549

487

424

362

299

236

173

111

48

30

1 Listed capacities may vary by approximately 10% due to inefficiencies that occur in fluid systems.


Blair Air System - Pump Sizes and Capacities 1
2" Plunger (Area 3.14 sq.in.)

Stroke In Inches

MAX - 2.88

H - 2.55

G - 2.22

F - 1.89

E - 1.56

D - 1.23

C - 0.91

B - 0.58

A - 0.25

Strokes/min

Litres/Day

4266

3779

3291

2805

2319

1831

1345

858

371

20

Litres/Day

5332

4724

4114

3507

1898

2290

1681

1072

463

25

Litres/Day

6399

5668

4705

4208

3478

2747

2017

1288

556

30

Imperial Gallons/Day

1407

1247

1035

925

765

604

443

283

122

30

1 Listed capacities may vary by approximately 10% due to inefficiencies that occur in fluid systems.


Blair Air System - Pump Sizes and Capacities 1
4" Air Cylinder - 5" Stroke; 62 cu.in./stroke

Volume at 20 strokes/min

0.727 scfm

43.62 scfh

1074 scfd

Volume at 25 strokes/min

0.909 scfm

54.54 scfh

1309 scfd

Volume at 30 strokes/min

1.091 scfm

65.46 scfh

1571 scfd

1 Listed capacities may vary by approximately 10% due to inefficiencies that occur in fluid systems.


Blair Air System - Pump Sizes and Capacities 1
6" Air Cylinder - 5" Stroke; 141 cu.in./stroke

Volume at 20 strokes/min

1.632 scfm

97.92 scfh

2350 scfd

Volume at 25 strokes/min

2.040 scfm

122.4 scfh

2938 scfd

Volume at 30 strokes/min

2.448 scfm

146.88 scfh

3525 scfd

1 Listed capacities may vary by approximately 10% due to inefficiencies that occur in fluid systems.